Tasha in a black dress checking her phone beside the PlantMate G3 controller and four houseplants. PlantMate G3 Firmware v2.0.3.

PlantMate G3 v2.0.3 brings clearer screens and better history

PlantMate G3 Main firmware v2.0.3 Build 002 and Display v1.7 are available for the PMWC-03. This release brings clearer plant cards, a better phone layout and more useful history to the four-zone touchscreen controller. It also makes SD files easier to find and adds a backup for recent watering records.

Check all four zones at a glance

The webpages keep G3’s familiar layout, with white backgrounds, readable bordered panels and clearer buttons. Plant card colours and labels help identify each zone’s mode and status. Tap a card to open its settings, start a Water now run from the card, or tap Stop watering to stop active watering.

On a phone, temperature, humidity and light stay in one row, with two plant cards across. Larger screens show all four plant cards across. The dashboard also shows whether automatic watering is on, off or paused, followed by recent watering with its date and time. Page footers identify the G3 and its local address.

PlantMate G3 desktop dashboard showing four coloured plant cards and temperature, humidity and light readings.
The desktop dashboard with sample plant data.
G3 phone dashboard with one row of environment cards and two plant cards across.
The phone dashboard with sample plant data.

Clearer touchscreen cards and plant icons

Display v1.7 uses colour across the full plant card. Clearer grey text improves readability in both light and dark themes, while the existing navigation stays familiar.

Larger icons make plants easier to recognise on the Home screen, in profiles and when choosing an icon. The eight choices cover Broad leaf, Long leaf, Cactus, Palm, Fern, Blossom, Succulent and a compact Plant group for a shared Timer Mode outlet.

PlantMate G3 display Home screen in dark mode with four coloured plant cards and larger plant icons.
The Display v1.7 Home screen, rendered with sample plant data.

Charts that show the data you have

The 24-hour, 7-day and 30-day charts place readings in their real calendar positions. Missing readings stay as gaps, and genuine zero-light readings remain visible. Environmental charts use calibrated readings, with light shown in lux. Soil moisture charts scale automatically on both the webpages and display to make smaller changes easier to see.

After restarting with a readable SD card, missing chart history can recover from compatible sensor logs once the device clock is valid. SD recovery uses the readings actually saved, normally every ten minutes.

Find your SD files and recover recent watering

Open History → Saved data (SD card files) to browse, view and download files. Newer years, months and dated files appear first.

  • Daily sensor readings go in /logs/YYYY/MM/YYYY-MM-DD-v203.csv.
  • Monthly watering events go in /events/YYYY/YYYY-MM.csv.
  • Recent watering is backed up to /events/watering-history.json.
  • Card instructions are in /readme.txt. G3 recreates this file when it is missing.

The JSON backup keeps the latest three full watering records per plant, including time, moisture before and after, duration and result. Existing internal records seed the backup at startup. Later backups run while pumps are idle. On restart, a valid backup can restore missing or damaged internal records for the dashboard, History page and display.

Watering counts and total time use this same retained record window. Valid internal histories take priority, and a factory reset prevents old backups from bringing deliberately erased records back. Older event CSVs remain available for reference, though they lack details needed for full watering-record recovery.

Keep local control without waiting for Wi-Fi

Continue without WiFi skips the startup network wait so the display and watering can operate locally. G3 can reconnect when Wi-Fi returns. The internet and SD card are optional for normal local operation. Scheduled watering needs a valid device clock.

The System menu’s QR code opens the local dashboard from a phone on the same network. When Wi-Fi is down or webpage files are unavailable, a message replaces the QR code. It returns when access is ready. After inserting an SD card, restart G3 to mount it and run history recovery.

Download the matched G3 release

Sign in for the latest Main 203 / Display 17 update files and instructions. Open the PlantMate G3 downloads

  • October Main v2.0.2 / Display v1.6, or earlier: Install the latest Main firmware and Main filesystem, plus matching Display v1.7 filesystem and firmware.
  • Already using the November SD folder and browser update with matching Display v1.7 files: Install the latest Main firmware for watering-history recovery.

Install Main firmware first with the SD card inserted. Let G3 restart and confirm /events/watering-history.json in Saved data before uploading Main filesystem. If updating the display, install Display filesystem first, then Display firmware, waiting for each update to finish. Browser-based Display updates require the SD card.

A Main filesystem upload replaces internal history. Available SD records can recover after restart. Keep any wanted logs before formatting a card, refresh the browser after updating, and follow the package’s filenames and checksums.

All Posts